Supply water leakage protection

Domestic system BB/UK

System BB/UK
Ill.: BB/UK3.5
spacer

Application:

Homes with normal water consumption pattern.
Components:
  • Intake flow meter
  • Cutoff valve
  • Control unit
spacer

Monitoring Functions


 

Leakage:
System BB/UK permits the continuous discharge of a preset amount of water. If this amount is exceeded in a single discharge, a Max Alarm is issued, and the water supply is cut off.
 

Seepage:
System BB/UK checks that water flow in the installation can drop and remain below a preset level for a preset time duration, and will issue a seepage alarm and cut off the water supply if this fails to occur daily.
 

System Error:
System BB/UK checks that the flow meter issues impulses regularly, unless the Holiday function is active.
Whenever the valve is closed - manually or by alarm -  System BB/UK checks its tightness.
If a component fails, a System Error is issued, and the water supply is cut off.
 

Supply Error:
System BB/UK monitors the mains supply and all internal supplies. If either of these fail, a Supply Error is issued. This may not cause a cutoff of the water supply.
 

Alarm Functions

On leakage and system errors, System BB/UK will cut off the water supply, issue visual and audible alarms, and activate the alarm relay.
Supply errors are reported via the alarm relay, and possibly also visibly and audibly.
 

Specifications

Controls and Indicators:
Mains, Flow, Valve and State indicators, buzzer.
Buttons for manual valve control, temporary free discharge selector, holiday function and alarm acknowledge.

Leakage monitor:
Permissible single discharge selectable 250, 500, 1000, or 2000 litres.
Other values available upon request.
Flow minimum to terminate discharge 0.6% Qn
In holiday mode, permissible single discharge is 20 litres regardless of setting.
Free discharge maximum duration selectable one to eight hours.

Seepage monitor:
Seepage tolerance 2, 4, or 8 litres in 30 or 60 minutes. Observation interval 24 hours.

Mains connection
230/240V 50Hz L/N/PE via external key switch. Power consumption max 20VA.

Options

Liquid Sensor Attachment:
System BB/UK accommodates via interface ILS-C up to two Liquid Sensors type LS-X, whereby the system offers point protection of particularly sensitive areas so that the water supply may be cut off on Liquid Sensor alarm if desired.


Installation diagram system BB/UK
 
system diagram BB/UK
1: Control Unit   2: Flow meter   3: Cutoff valve
spacer
System Capacity and pressure loss Dimensions
Nom. Cap.
Qn (m³/h)
 ΣΔp@Qn Equivalent
Kvs (m³/h)
(mwc) (kPa) Flow Meter Cutoff Valve
BB/UK-2.5 2.5 2.5 25 5.0 ¾" x 220/315 mm ¾" x 75 mm
BB/UK-3.5 3.5 2.5 25 7.0 1" x 260/375 mm 1" x 90 mm
BB/UK-6 6 2.5 25 12 1¼" x 220/315 mm 1¼" x 95 mm
BB/UK-10 10 2.5 25 20 1½" x 300/440 mm 1½" x 100 mm
BB/UK-15 15 2.5 25 30 2" x 300/460 mm 2" x 120 mm

EAN/UPC ordering codes here

spacer